Sensor
Description
Position
Riser1 Card
Entity presence
J47
Riser2 Card
Entity presence
J1000
RTC Battery
RTC battery status
U1055
SAS Cable
Entity presence
J6002
RAID Status
RAID controller card
health status
J157
DIMM
N
Memory DIMM status
DIMM.
N
indicates the
DIMM slot number.
PCIE Status
PCIe status error
J47 and J1000
PwrOn TimeOut
Power-on timeout
N/A
HDD Backplane
Entity presence
Front panel
Port# Link Down
Network port link status
Rear panel
SSD# Temp
ES3000 V3 temperature
This sensor is available
only when ES3000 V3 is
connected.
System Notice
Hot restart notice.
Collect error information
for the fault diagnosis
program.
N/A
System Error
System suspension or
restart. Check the
background logs.
N/A
RAID PCIE ERR
RAID controller card
fault diagnosis health
status
J157
PS Redundancy
Redundancy failure due
to PSU removal
PSU1\PSU2
BMC Boot Up
BMC startup events
N/A
SEL Status
SEL full or clearing
events
N/A
Op. Log Full
Operation log full or
clearing events
N/A
Sec. Log Full
Security log full or
clearing events
N/A
BMC Time Hopping
Time hopping
N/A
TaiShan X6000 Server
User Guide
A Appendix
Issue 04 (2020-06-05)
Copyright © Huawei Technologies Co., Ltd.
114