Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD3N Series User Manual V1.1
- 115 -
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F00.26
Action selection of HD3N
at zero-speed
Unit: Action selection of zero-speed
under V/f control
0: Do not process
1: HD3N does not output
2: HD3N runs at DC brake
Ten: Action selection of zero-speed
under open loop vector control
Hundred: Action selection of zero-
speed under torque control
0: Do not process
1: HD3N does nto output
2: HD3N runs at DC brake
3: HD3N runs at pre-excitation
111
1
×
F00.27
Command source binding
frequency source
Unit: keypad binds to frequency
source
Ten: Terminal binds to frequency
source
Hundred: SCI binds to frequency
source
0: No binding
1: Keypad digital
2; Terminal digital
3: SCI
5: Terminal pulse
7-8: AI1-AI2
b: Potentionmeter
C: PID
d: Multi-speed
000
1
×
F00.28
Function of STOP button
0: Valid in keypad control mode only
1: Valid in all control modes
0
1
○
F01: Protection of Parameters
( on pages 53 - 54
)
F01.00
User password
00000 - 65535
0
1
○
F01.01
Menu mode
Units:
0: Full menu mode
1: Checking menu mode
Ten: Unused
Hundreds:
0: Group F can check after setting
password
1: Group F can not check after
setting password
000
1
○