Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD3N Series User Manual V1.1
- 135 -
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F19.10
Zero frequency threshold
0.00 - upper limit frequency
1.00 Hz
0.01Hz
○
F19.11
Action selection when
setting frequency<zero
frequency threshold
0: Runs according to frequency
command
1: Remains stop and does not output
2: Runs according to zero frequency
3: Runs at 0Hz
0
1
×
F19.12
Non-stop at instantaneous
power loss
0: Forbid non-stop at instantaneous
power loss
1: Enable non-stop at instantaneous
power loss
0
1
×
F19.13
Voltage compensation
gain for non-stop running
0.010 - 1.000
0.500
0.001
○
F19.15
Voltage for action
judgement at
instantaneous power loss
400 - 670V
430V
1V
×
F19.16
Restart after power failure
0: Disabled
1: Enabled
0
1
×
F19.17
Waiting time for restart
after power failure
0.00 - 10.00s
2.00s
0.01s
○
F19.18
Overvoltage suppression
gain
0.000 - 1.000
0.000: Forbit
0.500
0.001
○
F19.19
Stall overvoltage point
650 - 790V
690V
1V
○
F19.20
Auto current limit gain
0.000 - 1.000
0.500
0.001
○
F19.21
Auto current limit
threshold
20.0 - 200.0%
150.0%
0.1%
○
F19.23
Terminal running
command detection
Unit: terminal selection when
powered on
Ten: terminal selection after powered
on
0: Edge is valid
1: Level is valid
00
1
○
F19.24
Action voltage of braking
unit
630 - 750V
680V
1V
○
F19.25
Flux braking
0: Disabled
1: Enable
0
1
○
F19.26
Setting length
0 - 65535m
0m
1m
○
F19.27
Actual length
0 - 65535m
0m
1m
*
F19.28
Length multiplying power
0.001 - 30.000
1.000
0.001
○
F19.29
Length correction
coefficient
0.001 - 1.000
1.000
0.001
○
F19.30
Axis diameter
1.00 - 100.00cm
10.00cm
0.01cm
○
F19.31
Pulse No. per rotate of
testing axis
1 - 9999
1
1
○
A