Shenzhen Hpmont Technology Co., Ltd.
Appendix A Parameters
HD3N Series User Manual V1.1
- 121 -
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F06.12
Multi-frequency
command 13
F00.09 - upper limit frequency
5.00Hz
0.01Hz
○
F06.13
Multi-frequency
command 14
F00.09 - upper limit frequency
5.00Hz
0.01Hz
○
F06.14
Multi-frequency
command 15
F00.09 - upper limit frequency
5.00Hz
0.01Hz
○
F06.15
Simple PLC control
selection
0: PLC is invalid
1: PLC is enabled
0
1
×
F06.16
Simple PLC running mode
selection
Unit: PLC running selection
0: Stop after single loop
1: Runs at final value after single loop
2: Continous loop
Ten: restart mode after stop during
PLC
0: Start from the first frequency
1: Start from the frequency when
HD3N stops
2: Runs at the moment when signal
loss
Hundred: PLC state saving selection
at power failure
0: Do not save
1: Save
Thousand: PLC phase time unit
0: Second (s)
1: Minute (m)
0000
1
×
F06.17
PLC phase 1 setting
Unit: PLC phase frequency selection
0: Multi frequency commmand
1: Set by F00.1
Ten: PLC phase direction selection
0: Forward
1: Reverse
2: Set by running command
Hundred: PLC phase Acc. / Dec. time
selection
0: Acc. / Dec. time 1
1: Acc. / Dec. time 2
2: Acc. / Dec. time 3
3: Acc. / Dec. time 4
4: Set by Acc. / Dec. speed
420
1
○
F06.19
PLC phase 2 setting
420
1
○
F06.21
PLC phase 3 setting
420
1
○
F06.23
PLC phase 4 setting
420
1
○
F06.25
PLC phase 5 setting
420
1
○
F06.27
PLC phase 6 setting
420
1
○
F06.29
PLC phase 7 setting
420
1
○
F06.31
PLC phase 8 setting
420
1
○
F06.33
PLC phase 9 setting
420
1
○
F06.35
PLC phase 10 setting
420
1
○
F06.37
PLC phase 11 setting
420
1
○
F06.39
PLC phase 12 setting
420
1
○
F06.41
PLC phase 13 setting
420
1
○
F06.43
PLC phase 14 setting
420
1
○
F06.45
PLC phase 15 setting
420
1
○
A