4.
Click
OK
.
5.
Type the serial number and press
Enter
.
6.
Select the Product ID field and press
Enter
.
The following alert appears:
Product ID is modified only by qualified personnel. This value must match the
product ID located on the chassis.
7.
Type the product ID and press
Enter
.
8.
Press
F10
to save the configuration.
The procedure is complete.
Restoring logical NVDIMMs after system board replacement
If the data in the logical NVDIMMs has changed since the last Scalable Persistent Memory backup operation
and the data has not been backed up using other means, the changed data will be lost.
The logical NVDIMMs (configuration and data) from the last Scalable Persistent Memory backup are stored
on the drives.
The logical NVDIMMs can be restored from the drives after the motherboard is replaced.
Procedure
1.
Launch the System ROM System Utilities by pressing the
F9
key during POST.
2.
Navigate to the
Scalable Persistent Memory Options
menu.
System configuration > BIOS/Platform Configuration (RBSU) > Memory Options > Persistent Memory
Options > Scalable Persistent Memory Options
3.
Set the Functionality field to
Enabled
.
4.
Select the
Recovery Options
submenu.
5.
Set the Restore Configuration field to
Enabled
.
6.
Select
F12: Save Changes and Exit
.
7.
Select
Yes - Save Changes
.
8.
Press the
Enter
key to reboot the server.
The configuration and data on the logical NVDIMMs will be restored during the system boot process.
HPE Trusted Platform Module 2.0 Gen10 Option
The HPE Trusted Platform Module 2.0 Gen10 Option is not a customer-removable part.
CAUTION:
If the TPM is removed from the original server and powered up on a different server, data
stored in the TPM including keys will be erased.
If you suspect a TPM board failure, leave the TPM installed and remove the system board (
on page 95). Contact a Hewlett Packard Enterprise authorized service provider
for a replacement system board and TPM board.
Removal and replacement procedures
99
Summary of Contents for ProLiant DL388 Gen10
Page 37: ...Customer self repair 37...
Page 38: ...38 Customer self repair...
Page 39: ...Customer self repair 39...
Page 147: ...Option 1 System board Option 2 Controller Option 3 not shown SAS Expander Cabling 147...
Page 149: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 149...
Page 151: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 151...
Page 152: ...Box 3 Cable routing Front 2SFF NVMe drive option for SFF 152 Cabling...