CAUTION:
Electrostatic discharge can damage electronic components. Be sure you are properly
grounded before beginning this procedure.
CAUTION:
Failure to properly handle DIMMs can cause damage to DIMM components and the system
board connector.
To identify NVDIMMs installed in the server, see "
"
Prerequisites
Before replacing memory, read the memory configuration and population guidelines in the server user guide.
Procedure
1.
Observe
2.
Power down the server (
on page 41).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
• Extend the server from the rack (
Extend the server from the rack
on page 42).
• Remove the server from the rack (
Remove the server from the rack
on page 42).
5.
Remove the access panel (
on page 44).
6.
Do one of the following:
• Remove the air baffle (
• Remove the 4 LFF midplane cage (
Removing and replacing a 4 LFF midplane cage
7.
Observe the NVDIMM LEDs. Do not remove an NVDIMM when any NVDIMM LED in the system is
illuminated.
8.
Remove the NVDIMM-N.
88
Removal and replacement procedures
Summary of Contents for ProLiant DL388 Gen10
Page 37: ...Customer self repair 37...
Page 38: ...38 Customer self repair...
Page 39: ...Customer self repair 39...
Page 147: ...Option 1 System board Option 2 Controller Option 3 not shown SAS Expander Cabling 147...
Page 149: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 149...
Page 151: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 151...
Page 152: ...Box 3 Cable routing Front 2SFF NVMe drive option for SFF 152 Cabling...