a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
• Extend the server from the rack (
Extend the server from the rack
on page 42).
• Remove the server from the rack (
Remove the server from the rack
on page 42).
4.
Remove the access panel (
on page 44).
5.
Do one of the following:
• Remove the air baffle (
• Remove the 4 LFF midplane cage (
Removing and replacing a 4 LFF midplane cage
6.
Remove the DIMM.
To replace the component, reverse the removal procedure.
For DIMM configuration information, see the server user guide.
DIMM-processor compatibility
The installed processor determines the type of DIMM that is supported in the server:
• First Generation Intel Xeon Scalable Processors support DDR4-2666 DIMMs.
• Second Generation Intel Xeon Scalable Processors support DDR4-2933 DIMMs.
Mixing DIMM types is not supported. Install only the supported DDR4-2666 or DDR4-2933 DIMMs in the
server.
Removing and replacing an NVDIMM
CAUTION:
Do not remove an NVDIMM when any LEDs on any NVDIMM in the system are illuminated.
Removing an NVDIMM when an LED is illuminated might cause a loss of data.
Removal and replacement procedures
87
Summary of Contents for ProLiant DL388 Gen10
Page 37: ...Customer self repair 37...
Page 38: ...38 Customer self repair...
Page 39: ...Customer self repair 39...
Page 147: ...Option 1 System board Option 2 Controller Option 3 not shown SAS Expander Cabling 147...
Page 149: ...Box 1 to SAS Expander Box 2 to SAS Expander Cabling 149...
Page 151: ...Cable routing Front 8SFF NVMe drive options Box 1 Box 2 Cabling 151...
Page 152: ...Box 3 Cable routing Front 2SFF NVMe drive option for SFF 152 Cabling...