To replace the component, reverse the removal procedure.
Removing and replacing a 4 LFF midplane cage
Procedure
1.
Power down the server (
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
• Extend the server from the rack (
Extend the server from the rack
on page 42).
• Remove the server from the rack (
Remove the server from the rack
4.
5.
If installed, remove all riser cages:
• Primary or secondary PCIe riser cage (
Removing and replacing the primary or secondary PCIe
• Tertiary PCIe riser cage (
Removing and replacing the tertiary PCIe riser cage
on page 55)
6.
Disconnect the power and cables from the drive cage.
7.
Raise the blue tabs on the drive tray and lift the drive cage to a 15 degree angle.
8.
Pull the plunger pin to disengage it.
9.
Remove all drives (
on page 46).
10.
Using both hands, remove the drive cage from the server.
74
Removal and replacement procedures