HP ProLiant server errors 82
Select "F2" to accept data loss and to re-enable logical drives
Audible Beeps
: None
Possible Cause
: Data was lost while the array was expanded; therefore, the drives have been temporarily
disabled. Capacity expansion failed due to:
•
Cache module or hard drive failed or was removed; expansion progress data lost
•
Expansion progress data could not be read from cache module
•
Expansion aborted due to unrecoverable drive errors
•
Expansion aborted due to cache module errors
Action
:
•
Press the
F1
key to continue with the logical drives disabled. Or, press the
F2
key to accept the data loss
and re-enable the logical drives.
•
Confirm errors using HP SSA.
•
Reseat the cache module, if possible.
•
Restore data from backup.
1770-Slot X Drive Array - Disk Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive model(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps
: None
Possible Cause
: Drive firmware update needed.
Action
: The indicated drives are running firmware that is known to cause intermittent problems. Update all
drives to the latest firmware version.
1774-Slot X Drive Array - Obsolete data found in Cache Module...
...Data Found in Cache Module was Older Than Data Found on Drives. Obsolete Data has been Discarded
Audible Beeps
: None
Possible Cause
: Drives were used on another controller and reconnected to the original controller while data
was in the original controller cache. Data found in the cache module is older than data found on the drives
and has been automatically discarded.
Action
: No action required
1775-Slot X Drive Array - Storage Enclosure Cabling Problem Detected: SAS Port Y:
OUT port of this box is attached to OUT port of previous box...
...Turn system and storage box power OFF and check cables. Drives in this box and connections beyond it will not be
available until the cables are attached correctly.
Audible Beeps
: None
Action