HP Onboard Administrator errors 206
The following table lists causes of the error, warning, or status events that appear.
Event
Cause
Bay Event
A bay was assigned or unassigned from a
group.
Blade Inserted
A blade was inserted into the enclosure.
Blade Thermal Status
Changed
The thermal status of a blade changed.
Blade Removed
A blade was removed from the enclosure.
Blade Port Map Info
The port mapping information of a blade was
updated.
Enclosure Status Change
A change in status has occurred because of a
change in the state of one or more hardware
components or server readings.
Enclosure Name Change
The name of the enclosure was changed.
Fan Status Change
The status of a fan has changed.
Fan Inserted
A fan has been inserted.
Fan Removed
A fan has been removed.
Interconnect Inserted
An interconnect module was inserted into the
enclosure.
Interconnect Thermal Status
Changed
The thermal status of an interconnect module
changed.
Interconnect Removed
An interconnect module was removed from the
enclosure.
Interconnect Power Reset
The power of an interconnect module was reset.
Interconnect Port Map Info
The port mapping information of an
interconnect module was updated.
LDAP Group Removed
A LDAP group was removed from the Onboard
Administrator. If you are logged into the
Onboard Administrator under this LDAP group,
you are disconnected.
OA System Log Cleared
The Onboard Administrator system log was
cleared.
OA Name Changed
The Onboard Administrator DNS name was
changed.
OA Inserted
A redundant Onboard Administrator was
inserted into the enclosure.
OA Removed
The redundant Onboard Administrator was
removed from the enclosure.
OA Takeover
The redundant and active Onboard
Administrators are switching roles. The Active
Onboard Administrator reboots into Standby
Mode and the redundant Onboard
Administrator transitions to Active Mode.
Power Supply Status Change The status of a power supply has changed.
Power Supply Inserted
A power supply has been inserted.
Power Supply Removed
A power supply has been removed.
Power Supply Redundancy
Change
The power supplies are either now redundant or
are no longer redundant.
Power Supply Overload
The power supplies are being asked to draw