HP ProLiant server errors 55
- System Halted!
Possible cause:
The memory channel is not populated in the correct order.
Action:
See the server user guide for corrective action.
229- DIMM Configuration Error - Processor X, DIMM Y
- Unsupported DIMM. - System Halted!
Possible cause:
An unknown DIMM type was detected.
Action:
Install the correct DIMM type.
230- DIMM Configuration Error - Processor X, Channel Y
- Only 2 DIMMs can be installed on a channel containing Quad-Rank DIMM(s).
- System Halted!
Possible cause:
Too many DIMMs are installed on a channel containing Quad Rank DIMMs.
Action:
Ensure there are only two DIMMs installed on the channel.
231- DIMM Configuration Error
- No memory is available. If DIMMs are installed, verify that the corresponding processor is installed. - System Halted!
Possible cause:
No DIMMs are installed in the system or no DIMMs are installed for which there is a
corresponding processor.
Action:
Install DIMMs or verify there is a corresponding processor for the installed DIMMs.
232- Memory initialization error - Processor X, DIMM Y failed.
- No usable memory detected. - System Halted!
Possible cause:
All of the installed memory failed the memory test.
Action:
Replace the memory.
233- DIMM initialization Error - Memory access locked by LT.
Possible cause:
Memory access is locked by TXT.
Action:
Contact HP support.
233- Trusted Execution Technology (TXT) Failure- Secrets in Memory detected and
BIOS may be compromised
...System halted.
Action:
Remove server battery for at least 1 minute to allow the system to boot.
234- DIMM Initialization Error - Receive Enable error. Cannot train memory.
Possible cause:
The system receives a Receive Enable error during memory training.
Action:
Contact HP support.