Microsoft Windows Event ID and SNMP traps 327
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaPhyDrvCntlrIndex
•
cpqDaPhyDrvIndex
•
cpqDaPhyDrvLocationString
•
cpqDaPhyDrvType
•
cpqDaPhyDrvModel
•
cpqDaPhyDrvFWRev
•
cpqDaPhyDrvSerialNum
•
cpqDaPhyDrvFailureCode
•
cpqDaPhyDrvStatus
•
cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaCntlrHwLocation
•
cpqDaSpareCntlrIndex
•
cpqDaSparePhyDrvIndex
•
cpqDaSpareStatus
•
cpqDaSpareLocationString
•
cpqDaSpareDrvBusNumber
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”
NT Event ID: 1218 (Hex)0x843504c2 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to %5 of the controller in%4 has a new status of %2.