HP ProLiant server errors 70
1611-Redundant Fan Failure (Fan Zone System)
Audible Beeps
: None
Possible Cause
: A redundant fan is not spinning.
Action
: Replace the failed fan.
1612-Primary Power Supply Failure
Possible Cause
: Primary power supply has failed.
Action
: Replace the power supply.
1615-Power Supply Configuration Error
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps
: None
Possible Cause
: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action
: Install the additional power supply.
1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure
in Bay X
Audible Beeps
: None
Possible Cause
: The power supply has failed, or it is installed but not connected to the system board or AC
power source.
Action
: Reseat the power supply firmly and check the power cable or replace power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps
: None
Possible Cause
: Power supply is improperly configured.
Action
: Run the server setup utility and correct the configuration.
1623- Power Supply Unplugged – Power Supply X is unplugged
Action:
Replace the power supply.