HP Smart Array errors 135
•
PHY_RESET_FAILED - Phy reset request failed.
•
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
•
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
•
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
•
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that
is too small.
•
OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
•
OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation
has completed on it but it hasn’t been replaced yet.
Message Id: 24710
Severity: Informational
Log message:
The external Smart Array controller located in the MSA chassis labeled as <chassis
label> has reported that logical drive <logical drive number> has encountered
a status change from:
Status: <previous status>
to
Status: <current status>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<previous status> and <current status> values:
•
“
OK
”
•
“
FAILED
”
•
“
NOT CONFIGURED
”
•
“
INTERIM RECOVERY MODE
”
•
“
READY FOR RECOVERY
”
•
“
RECOVERING
”
•
“
WRONG PHYSICAL DRIVE REPLACED
”
•
“
PHYSICAL DRIVE NOT PROPERLY CONNECTED
”
•
“
HARDWARE IS OVERHEATING
”
•
“
HARDWARE HAS OVERHEATED
”
•
“
EXPANDING
”
•
“
NOT YET AVAILABLE
”
•
“
QUEUED FOR EXPANSION
”
•
“
DISABLED DUE TO SCSI ID CONFLICT
”
•
“
EJECTED
”