Microsoft Windows Event ID and SNMP traps 307
NT Event ID: 1180 (Hex)0x8435049c (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Library Status Change.
Log Message: The tape library in slot %4, SCSI bus %5, SCSI target %6 has a new status of %7
SNMP Trap: cpqDa2TapeLibraryStatusChange - 3031 in CPQIDA.MIB
Symptom: Tape Library Status Change. This trap indicates that the agent has detected a change in the status
of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable
cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.
User Action: If the tape library is failed, check the tape library front panel.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaTapeLibraryCntlrIndex
•
cpqDaTapeLibraryScsiBus
•
cpqDaTapeLibraryScsiTarget
•
cpqDaTapeLibraryScsiLun
•
cpqDaTapeLibraryModel
•
cpqDaTapeLibraryFWRev
•
cpqDaTapeLibrarySerialNumber
•
cpqDaTapeLibraryStatus
Supporting SNMP Trap Description: “Status is now [cpqDaTapeLibraryStatus] for the tape library.”
NT Event ID: 1181 (Hex)0x8435049d (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Library Door Status Change.
Log Message: The tape library in slot %4, SCSI bus %5, SCSI target %6 has a new door status of %7.
SNMP Trap: cpqDaTapeLibraryDoorStatusChange - 3021 in CPQIDA.MIB
Symptom: Tape Library Door Status Change. This trap indicates that the agent has detected a change in the
door status of a tape library. The variable cpqDaTapeLibraryDoorStatus indicates the current tape library
door status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.
User Action: If the tape library door is open, close the tape library door.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqDaTapeLibraryCntlrIndex
•
cpqDaTapeLibraryScsiBus
•
cpqDaTapeLibraryScsiTarget