HP Smart Array errors 130
Log message:
A SAS link error has been detected between port <port number> of array
controller <controller name / slot information> and <attached device><attached
device index>. Please check this data path and the associated hardware.
<attached device> values:
•
“
an expander
”
•
“
another controller
”
•
“
a hard drive in bay
“
•
“
an unknown internal device
”
Message Id: 24693
Severity: Warning
Log message:
A SAS link error has been detected from the onboard expander of array
controller <controller name / slot information>. Please check this controller
to ensure it is functioning properly.
Message Id: 24694
Severity: Warning
Log message:
A SAS link error has been detected between a Smart Array controller's
onboard expander and an externally attached storage box. The error was detected
between port <port number> of array controller <controller name / slot
information> and I/O module number <module number> located in box number <box
number>. Please check this data path and the associated hardware.
Message Id: 24695
Severity: Warning
Log message:
A SAS link error has been detected between the onboard expander (port
<port number>) of array controller <controller name / slot information> and
<attached device><attached device index>. Please check this data path and the
associated hardware.
Message Id: 24696
Severity: Warning
Log message:
A SAS link error has been detected between I/O module <module number
1> of box <box number 1> and I/O module <module number 2> of box <box number 2>.
These boxes are connected to port <port number> of array controller <controller
name / slot information>. Please check this data path and the associated hardware.
Message Id: 24697
Severity: Warning
Log message:
A SAS link error has been detected in bay <bay number> of box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. Please check this data path and the associated hardware.
Message Id: 24698
Severity: Warning
Log message:
A SAS link error has been detected between array controller <controller
name / slot information> and the switch expander connected to port <port number>
of this controller. Please check this data path and the associated hardware.