Microsoft Windows Event ID and SNMP traps 326
•
cpqSsBoxBusIndex
•
cpqSsBoxVendor
•
cpqSsBoxModel
•
cpqSsBoxSerialNumber
•
cpqSsBoxFltTolPwrSupplyStatus
Supporting SNMP Trap Description: “Storage system power supply status changed to
[cpqSsBoxFltTolPwrSupplyStatus].”
NT Event ID: 1215 (Hex)0x843504bf (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Fibre Channel Controller Status Change.
Log Message: The Fibre Channel Controller in %4 has a new status of %5.
SNMP Trap: cpqFca3HostCntlrStatusChange - 16028 in CPQFCA.MIB
Symptom: Fibre Channel Host Controller Status Change. This trap indicates that the agent has detected a
change in the status of a Fibre Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the
current controller status.
User Action: If the controller status is failed, replace the controller.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqFcaHostCntlrHwLocation
•
cpqFcaHostCntlrIndex
•
cpqFcaHostCntlrStatus
•
cpqFcaHostCntlrModel
•
cpqFcaHostCntlrSerialNumber
•
cpqFcaHostCntlrWorldWideName
•
cpqFcaHostCntlrWorldWidePortName
Supporting SNMP Trap Description: “Host controller has a new status of [cpqFcaHostCntlrStatus].”
NT Event ID: 1216 (Hex)0x843504c0 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in %4, %5 with serial number “%7”, has a new status of %2.
SNMP Trap: cpqDa7PhyDrvStatusChange - 3046 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current physical drive status.
User Action: If the physical drive status is failed(3), predictiveFailure(4), ssdWearOut(8) or
notAuthenticated(9) replace the drive.
Supporting SNMP Trap Data: