Environmental specifications
Specification
Value
System Inlet Temperature, Extended Ambient
Operating Support
—
—
For approved hardware configurations, the supported
system inlet range is extended to be 5°C to 10°C
(41°F to 50°F) and 35°C to 40°C (95°F to 104°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
—
For approved hardware configurations, the supported
system inlet range is extended to be 40°C to 45°C
(104°F to 113°F)
All temperature ratings shown are for sea level with
an altitude derating of 1.0 °C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft).
1
1
System performance may be reduced if operating in the extended ambient operating range or with a fan
fault.
The approved hardware configurations for this system are listed on the
.
Mechanical specifications
Specification
Value
Height
8.75 cm (3.44 in)
Depth
75.47 cm (29.71 in)
Width
44.54 cm (17.54 in)
Weight (maximum)
34.12 kg (75.23 lbs)
Weight (minimum)
18.45kg (40.67 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 800W Flex Slot Platinum Hot Plug Low Halogen Power Supply
on page 118
•
HPE 800W Flex Slot Titanium Hot Plug Low Halogen Power Supply
on page 118
•
HPE 800W Flex Slot Universal Hot Plug Low Halogen Power Supply
on page 119
•
HPE 800W Flex Slot -48VDC Hot Plug Low Halogen Power Supply
on page 120
•
HPE 1600W Flex Slot Platinum Hot Plug Low Halogen Power Supply
Environmental specifications
117
Summary of Contents for ProLiant DL560 Gen10
Page 6: ...Warranty information 124 Regulatory information 125 Documentation feedback 125 6 Contents ...
Page 27: ...Customer self repair 27 ...
Page 28: ...28 Customer self repair ...
Page 29: ...Customer self repair 29 ...
Page 30: ...30 Customer self repair ...
Page 102: ...16 SFF backplanes Group C SAS cables 102 Cabling ...
Page 113: ...Quad slimline riser installed in the secondary PCIe riser cage Tertiary riser Cabling 113 ...