Extend the server from the rack..............................................................................................33
Removing the server from the rack.........................................................................................34
Accessing the Systems Insight Display.................................................................................. 34
Releasing the cable management arm .................................................................................. 35
Removing the access panel....................................................................................................35
Removing the bezel...........................................................................................................................36
Removing and replacing a drive blank.............................................................................................. 37
Removing and replacing a hot-plug SAS or SATA drive....................................................................37
Removing and replacing an NVMe drive........................................................................................... 38
Removing and replacing the air baffle............................................................................................... 39
Removing and replacing the fan cage............................................................................................... 40
Removing and replacing the fan cage louvers.................................................................................. 41
Removing and replacing the hot-plug fan..........................................................................................42
Removing and replacing the processor mezzanine tray....................................................................43
Removing and replacing a processor-heatsink module.....................................................................43
Removing and replacing a DIMM...................................................................................................... 47
Removing and replacing the 2P pass-through performance board................................................... 48
Removing and replacing a 4-port NVMe mezzanine card................................................................. 49
Removing and replacing a Systems Insight Display or Power Switch module..................................50
Removing and replacing a PCIe riser cage....................................................................................... 51
Removing an expansion slot blank....................................................................................................52
Removing and replacing an expansion board................................................................................... 53
Removing and replacing the HPE 12G SAS Expander Card............................................................ 54
Removing and replacing a riser board...............................................................................................55
Removing and replacing the FlexibleLOM.........................................................................................56
Removing and replacing a Smart Storage Battery............................................................................ 57
Removing and replacing an eight-bay SFF HDD cage......................................................................58
Removing and replacing an eight-bay NVMe SSD drive cage.......................................................... 59
Removing and replacing a universal media bay................................................................................60
Removing and replacing a two-bay SFF drive cage..........................................................................61
Removing and replacing the optical drive..........................................................................................62
Removing and replacing a power supply blank................................................................................. 64
Removing and replacing a power supply...........................................................................................64
Removing and replacing a Smart Array controller.............................................................................65
Removing and replacing an intrusion detection switch......................................................................66
Replacing the system battery............................................................................................................ 67
Removing and replacing the system board....................................................................................... 68
HPE Trusted Platform Module 2.0 Gen10 Option............................................................................. 69
Selecting the boot mode ........................................................................................................ 72
Secure Boot............................................................................................................................ 73
Launching the Embedded UEFI Shell ....................................................................................73
4
Contents
Summary of Contents for ProLiant DL560 Gen10
Page 6: ...Warranty information 124 Regulatory information 125 Documentation feedback 125 6 Contents ...
Page 27: ...Customer self repair 27 ...
Page 28: ...28 Customer self repair ...
Page 29: ...Customer self repair 29 ...
Page 30: ...30 Customer self repair ...
Page 102: ...16 SFF backplanes Group C SAS cables 102 Cabling ...
Page 113: ...Quad slimline riser installed in the secondary PCIe riser cage Tertiary riser Cabling 113 ...