CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all device bays are
populated with either a component or a blank.
Procedure
1.
Release the cable management arm to access the rear panel (
Releasing the cable management arm
on page 35).
2.
Remove the power supply.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
Removing and replacing a Smart Array controller
CAUTION:
Hewlett Packard Enterprise recommends performing a complete backup of all server data before
installing or removing a controller or adapter.
Procedure
1.
Back up all server data.
2.
Power down the server (
on page 33).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
Removing and replacing a Smart Array controller
65
Summary of Contents for ProLiant DL560 Gen10