Hardware options installation 65
Item Description
Definition
1
Capacity
8 GB
16 GB
32 GB
2
Rank
1R = Single-rank
2R = Dual-rank
4R = Quad-rank
3
Data width
x4 = 4-bit
x8 = 8-bit
4
Memory generation DDR4
5
Maximum memory
speed
2133 MT/s
6
CAS latency
P=15
7
DIMM type
R = RDIMM (registered)
L = LRDIMM (load reduced)
E = UDIMM (unbuffered with ECC)
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/qs
).
Memory configurations
To optimize server availability, the server supports Advanced ECC AMP mode:
•
Advanced ECC—Provides up to 4-bit error correction. This mode is the default option for this server.
Advanced Memory Protection options are configured in the BIOS/Platform Configuration (RBSU). If the
requested AMP mode is not supported by the installed DIMM configuration, the server boots in Advanced
ECC mode. For more information, see the
HPE UEFI System Utilities User Guide for HPE ProLiant Gen9
Servers
on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/ProLiantUEFI/docs
).
Maximum memory capacity
DIMM type
DIMM rank
One Processor
UDIMM
Single-rank (4 GB)
16 GB
UDIMM
Single-rank (8 GB)
32 GB
UDIMM
Dual-rank (8 GB)
32 GB
UDIMM
Dual-rank (16 GB)
64 GB
For the latest memory configuration information, see the product QuickSpecs on the Hewlett Packard
Enterprise website (
http://www.hpe.com/info/docs
).
Advanced ECC memory configuration
Advanced ECC memory is the default memory protection mode for this server. Standard ECC can correct
single-bit memory errors and detect multi-bit memory errors. When multi-bit errors are detected using
Standard ECC, the error is signaled to the server and causes the server to halt.
Advanced ECC protects the server against some multi-bit memory errors. Advanced ECC can correct
both single-bit memory errors and 4-bit memory errors if all failed bits are on the same DRAM device on
the DIMM.
Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain
memory errors that would otherwise be uncorrected and result in a server failure. Using HPE Advanced
Memory Error Detection technology, the server provides notification when a DIMM is degrading and has a
higher probability of uncorrectable memory error.
Summary of Contents for hpe proliant dl20 gen9
Page 14: ...Component identification 14 2 bay LFF non hot plug drive model 2 bay LFF hot plug drive model ...