Software and configuration utilities 104
FWUpdate command from within the Embedded UEFI Shell
For systems configured in either boot mode, update the firmware:
1.
Access the System ROM Flash Binary component for your server from the Hewlett Packard
Enterprise Support Center website (
http://www.hpe.com/support/hpesc
). When searching for the
component, always select
OS Independent
to locate the binary file.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
Boot to Embedded Shell.
5.
To obtain the assigned file system volume for the USB key, enter
Map –r
. For more information
about accessing a file system from the shell, see the
UEFI Shell User Guide for ProLiant Gen9
Servers
on the Hewlett Packard Enterprise website (
http://www.hpe.com/info/ProLiantUEFI/docs
).
6.
Change to the file system that contains the System ROM Flash Binary component for your server.
Enter one of the fsx file systems available, such as
fs0
or
fs1
, and press
Enter
.
7.
Use the
cd
command to change from the current directory to the directory that contains the binary
file.
8.
Enter
fwupdate –d BIOS -f <filename>
to flash the system ROM.
For help on the FWUPDATE command, enter the command:
help fwupdate -b
9.
Reboot the server. A reboot is required after the firmware update for the updates to take effect and
for hardware stability to be maintained.
For more information about the commands used in this procedure, see the
UEFI Shell User Guide for
ProLiant Gen9 Servers
on the Hewlett Packard Enterprise website
(
http://www.hpe.com/info/ProLiantUEFI/docs
).
Firmware Update application in System Utilities
For systems configured in either boot mode, update the firmware:
1.
Access the System ROM Flash Binary component for your server from the Hewlett Packard
Enterprise Support Center website (
http://www.hpe.com/support/hpesc
). When searching for the
component, always select
OS Independent
to find the component.
2.
Copy the binary file to a USB media or iLO virtual media.
3.
Attach the media to the server.
4.
During POST, press
F9
to enter System Utilities.
5.
Select
Embedded Applications
→
Firmware Update
→
System ROM
→
Select Firmware File
.
6.
Select the device containing the flash file.
7.
Select the flash file. This step may take a few moments to complete.
8.
Select
Start firmware update
and allow the process to complete.
9.
Reboot the server. A reboot is required after the firmware update for the updates to take effect and
for hardware stability to be maintained.
Online Flash components
This component provides updated system firmware that can be installed directly on supported Operating
Systems. Additionally, when used in conjunction with the HP SUM ("
HP Smart Update Manager
" on page
98
), this Smart Component allows the user to update firmware on remote servers from a central location.
This remote deployment capability eliminates the need for the user to be physically present at the server
to perform a firmware update.
Summary of Contents for hpe proliant dl20 gen9
Page 14: ...Component identification 14 2 bay LFF non hot plug drive model 2 bay LFF hot plug drive model ...
Page 88: ...Cabling 88 2 bay LFF non hot plug configuration Optical drive cabling 2 LFF configuration ...
Page 92: ...Cabling 92 2 bay LFF hot plug drive configuration ...
Page 120: ...Support and other resources 120 ...
Page 121: ...Support and other resources 121 ...