A-6
Appendix A
MPE/iX Configuration and SYSGEN
Configuring the Remote Console
Configuring the Remote Console
This section describes the correct configuration for the 99x remote console. The remote
console port is used by the Response Center to view the contents of the support processor.
HP Predictive can also use this port when it is correctly configured.
NOTE
MPE/iX 5.0 and later releases should have LDEV 21 properly set for the
remote console, so you should not have to perform this procedure.
Earlier releases may or may not have LDEV 21 properly set.
The Problem
The former default configuration for LDEV 21 specified an HPC2204A "Bifocus" disk drive.
Since remote console and HP Predictive Support can use LDEV 21 as the dial up port, it is
important for this port to be configured correctly. The default configuration will cause
Predictive Support to abort with the following error messages on the console:
CTL(17) Cannot FOPEN port on LDEV 21 (FSERR 56)
CTL(7)
Terminating Transfer Attempt
To fix this, the default configuration for LDEV 21 for the 99x has to be changed to
HP28639-60001 console terminal.
Procedure
To change an improper configuration for LDEV 21:
1. Call up the SYSGEN program:
: SYSGEN
2. Activate the IO Configurator by entering:
sysgen> IO
Summary of Contents for 3000 99x Family
Page 8: ...Contents 6 Figures ...
Page 10: ...Contents 8 Tables ...
Page 12: ...Preface 2 ...
Page 18: ...Preface 8 ...
Page 20: ...Preface 10 ...
Page 21: ...Chapter 1 1 1 Introduction 1 Introduction ...
Page 30: ...1 10 Chapter1 Introduction Orientation Figure 1 2 SPU Cabinet Internal Layout Front ...
Page 31: ...Chapter 1 1 11 Introduction Orientation Figure 1 3 SPU Cabinet Internal Layout Rear ...
Page 32: ...1 12 Chapter1 Introduction Orientation ...
Page 33: ...Chapter 2 2 1 Unpacking and Inspection 2 Unpacking and Inspection ...
Page 48: ...2 16 Chapter2 Unpacking and Inspection Repackaging the Cabinet for Shipment ...
Page 68: ...3 20 Chapter3 Installation PMB Cards Figure 3 7 Inserting Removing a PMB Card ...
Page 126: ...3 78 Chapter3 Installation Operating the Computer ...
Page 143: ...Appendix B B 1 Configuring the HP PB Card Cage B Configuring the HP PB Card Cage ...
Page 151: ...Appendix C C 1 Configuring the Remote Support Modem C Configuring the Remote Support Modem ...
Page 168: ...C 18 AppendixC Configuring the Remote Support Modem Console LAN Card Modem Line Behavior ...
Page 169: ...Appendix D D 1 Power Resiliency D Power Resiliency ...
Page 171: ...Appendix D D 3 Power Resiliency Power System Figure D 1 PFC Module Locations ...