To Test the Field Windings:
Set the multi-meter to ohms
Ω
and place one probe into terminal 7 on the module
connecting block and the other in terminal 6 (see picture on previous page). The reading
should be about 1.25
Ω
. No reading would indicate faulty windings or a break in the wire.
To test the split field (Only on machines over 1000 spin) Place one meter probe in either
terminal 6 or 7 and the other probe in terminal 10 on the module connecting block. The
reading should be about 0.5
Ω
.
To Test the Tacho:
Set the multi-meter to ohms
Ω
and place one probe into terminal 4 on the module
connecting block and the other in terminal 5 (see picture on previous page). The reading
should be about 135
Ω
. However unless you have a digital meter you won’t be able to
determine the exact reading, just that the needle is between 100
Ω
and 200
Ω
. If there is
no reading it could be the wire is broken or you have a faulty connection or the tacho
itself is faulty.
1.3
Date Code Information
The date code/serial numbers is normally located on the inside of the door by the hinge.
The first 2 digits of the serial number are the Date code, so by using the chart below you
can tell exactly when your machine came of the production line.( As opposed to when the
store sold it.) Therefore the example serial number of 23290056 shows the machine came
of the production line in November 2003.
JAN
FEB
MAR APR
MAY JUN
JUL
AUG
SEP
OCT NOV DEC
2000
73
74
75
76
77
78
79
80
81
82
83
84
2001
85
86
87
88
89
90
91
92
93
94
95
96
2002
01
02
03
04
05
06
07
08
09
10
11
12
2003
13
14
15
16
17
18
19
20
21
22
23
24
2004
25
26
27
28
29
30
31
32
33
34
35
36
2005
37
38
39
40
41
42
43
44
45
46
47
48