background image

Operating Manual

EN

Neptun SC1

Summary of Contents for Neptun SC1

Page 1: ...Operating Manual EN Neptun SC1...

Page 2: ...machine will result in cancellation of the declaration of conformity issued by the manufacturer distributor and sign as well Use the machine only in closed rooms Operation is only permissible at ambi...

Page 3: ...mentally friendly and recyclable Please help by disposing of the packaging in an environmentally friendly manner The packaging must not be given to children to play with There is a risk of suffocation...

Page 4: ...brush with flexible PVC hose and ball valve 1 2 hand brush with flexible PVC hose and ball valve 1 2 Detergent canister not belonging to the machine Push button Brush 150 mm can be easily removed wit...

Page 5: ...male dosing system Inlet for transparent silicone hose dosing system platform to store detergent canister grid when closed lockable by bracket clamping nylon roller brush 150 mm length 330 mm Inlet fo...

Page 6: ...The machine is not equipped with an upstreamed return valve and water filtre If necessary return valve and water filtre have to be installed before the unit The requested water quantity can be indiviu...

Page 7: ...ing Rotation of roller brush will start Solenoid valve of the dosing system opens and starts spraying water and detergents on the rotating roller brush Release push button to stop the sole cleaning pr...

Page 8: ...transparent silicone hose of the dosing system Rinse through the dosing system to remove residues In case of unintended opening of the grid the roller brush stops automatically and the solenoid valve...

Page 9: ...aning of brushes once a month Cleaning of dosing system once a month strictly when changing the medium Change of roller brush every 5 7 years earlier when worn Cleaning surfaces The surface is made of...

Page 10: ...located at front side of the brush with suitable tool and pull off the distance washer Fig 14 4 Now the brush can be pulled off the axle Fig 15 5 When assembling put the pin in the center position of...

Page 11: ...e hose on to the return valve Take care that the hose is wholly plugged and is not bended Dosing system The dosing system prepares the mixture of water and detergent disinfectant in a certain proporti...

Page 12: ...d mixture use products having the same viscosity than water water viscosity of 1 Media having higher viscosity semifluid could cause problems Dosing system rinsing We recommend to rinse the system for...

Page 13: ...check it close the valve completely and find out if the liquid will be absorbed Suction effect visible Suction effect not visible Qualified personnel should replace it If the detergent is not absorbed...

Page 14: ...osed or interrupted Check water supply Machine does not drain off waste water Water outlet is blocked Check water outlet if necessary remove blockage Motor stops or runs unproperly Foreign objects ins...

Page 15: ...9 0V AC 03 1 2gG N 1 2 F2 56015005 10x38 32A P1 P2 S1 S2 T1 ABL6TS04B 40VA 230 400V 24V 0 5aM 1 2 3 4 F1 56010020 10x38 32A 24V AC 03 1 Wiring diagram I Wiring diagram II 1 2 3 4 5 6 7 8 9 10 11 12 1...

Page 16: ...ductor 3 3 3 3 Conductor 1 03 9 FDC 1 4 5 4 5 4 Conductor 2 03 9 Conductor 3 2 2 2 Conductor 2 03 5 1 1 1 Conductor 1 03 5 AU 21 6 6 6 Conductor 2 03 9 KM1 A1 Conductor 3 8 8 8 Conductor 2 03 12 EV 1...

Page 17: ...atron GSE 06800107 8 Nut Perfect CEPFV36 06800108 9 Gasket for connection piece PG36 06800109 10 Connection piece grey PG36 06800110 11 PVC hose GP 40 x 46 2 lg length 2 m 06800111 12 Dosing device ch...

Page 18: ...only the technical base at the time of delivery of the goods in combination with this manual by Maschinenfabrik HEUTE GmbH Co KG The products and their design are subject to constant changes improveme...