Honeywell
11
Figure 2-6 DIP Switches of HVBNET16CPU
DIP switch 1 is used to set communication parameters for the three serial ports.
Position
Use
Description
SW 1
SW 2
Com 1 port baud rate
setting
SW 3
SW 4
Com 2 port baud rate
setting
SW 5
SW 6
Com 3 port baud rate
setting
SW2/SW4/SW6 SW1/SW3/SW5
BAUD
RATE
0 0
9600
0 1
19200
1 0
38400
1 1
57600
SW 7
Switch Com1 between
NETCPU & NETOSD
0= NETOSD
1= NETCPU
SW 8
Com 1 usage.
0 = Show Linux debug info
1 = Set COM1 to be used for third-party
integration
DIP switch 2 is used to restore, set communications parameters and set video source.
Position
Use
Description
SW 1
Restore factory setting
To set to factory settings, set it to 1 during
reset. Then set it back to 0. (System IP will be
initialed together, the default IP is 192.168.1.9)
SW 2
Com 1 type
0= RS-232
1= RS-422
SW 3
Com 2 type
0= RS-232
1= RS-422
SW 4
SW 5
Com 3 type
SW5 SW4 Type
0 0 RS232
0 1 RS422
1 0 RS485
1 1 Reserved