The following table shows commands available for use in sequence editing:
COMMAND
PARAMETER
NUMBER1
PARAMETER
NUMBER2
PARAMETER
NUMBER3
PARAMETER
NUMBER4
DESCRIPTION
END
Terminates
this
Sequence
RESTART
Restart
Sequence
from
Step Number1
NOP
No
Operation
SWITCH
Input Channel
Output
Channel
Switch Video Input to
Video Output
SCENE
Group Number
Scene Number
View Number
Monitor number
Select Scene
NEXTCAM
Output
Select next camera
COPYMON
Source Monitor
Destination
Monitor
Copy displayed camera to
another monitor
DELAY
Number of
Minutes
Number of
Seconds
Wait for specified time
delay
START
Sequence
Number
Start another Sequence
STOP
Sequence
Number
Stop another Sequence
CALL
Sequence
Number
Call another Sequence as
a sub-routine