Honeywell
113
Steps for Configuring Sequence Group Names
1. Select a group number to use.
NOTE:
Group number is an editable text field capable of accepting numeric values.
In the database, the group number is still defined as originally set.
For example, default values are shown as 1, 2, 3, 4, etc. If “2” is revised to be “23”, the
list will display as 1, 23, 3, 4, etc. and the original row 23 remains the same. We
recommend that the Group Number field NOT be revised.
2. Modify the text in the Group Name field to a meaningful means of grouping
sequences. Once the group name is modified, the values will be carried over into
other applicable windows.
3. Select
to save/download all information from the current page.
Sequence Examples
The examples provided are generic examples. They may or may not be of use
depending on your equipment and particular setup.
Camera Switching Sequence
This sequence is based on the following commands:
SWITCH
Parm1 – The camera or Input number.
Parm2 – The monitor number to which the camera in Parm1 will be
switched.
Note:
Setting Parm 2 to 0 will switch the camera to the monitor that the user is currently
logged into.
DELAY
Parm1 – Delay in Minutes. Min. 0 for no minutes and max 255 minutes.
Parm2 – Delay in Seconds. Min. 0 for no seconds and max 60 seconds.
Summary of Contents for VideoBloX
Page 1: ...800 04465 April 2008 Rev A VideoBloX Matrix Switcher User Manual ...
Page 2: ...Revision History ISSUES DATE REVISIONS A Apr 2009 Initial Release ...
Page 16: ......
Page 55: ...Honeywell 39 Figure 2 56 SW 3 and SW 4 settings for interlink input module ...
Page 163: ...Honeywell 147 ...
Page 179: ...Honeywell 163 Note Device key codes please refer to command DEVICE ...