LYNX Touch Installation and Setup Guide
- 35 -
Programming the Control
Program Zones
The following system options are programmed in this section:
Option Function
Serial Number
Manually enter device serial number or enroll via RF transmission
Loop Number
Manually enter device loop number or enroll via RF transmission
Zone Description 1/2
Enter Zone Descriptors for the device being enrolled
Device Type
Select the type of device being enrolled
Response Type
Select the alarm response for the device being enrolled (refer to Zone Response Type Table)
Alarm Report
Activate reporting option for the device being enrolled
Chime
Enable/disable chime mode for specific device being enrolled (applies to Entry/ Exit, Perimeter,
and Interior Response types only)
Supervision
Select supervision for device being enrolled
Arm Night
Allows specific programmed motion sensors to be bypassed by the User when Arm Night mode
is enabled and the system is Armed in Stay mode.
Note:
If applicable, preprogrammed defaults for the L5200/L7000 Control are shown on the screen unless otherwise noted.
SCREEN ACTION
5000-100-133-V0
Zones
1.
Select “Zones”
The System displays the following options:
1. New
3. Back Door
5. Motion Sensor
2. Front Door
4.Window
6.New
2. Use the down
arrow to scroll to the next page of options. Use the
arrow to return to
the previous page.
7. – 45. New
46. – 48 New (Main) (reserved for Garage Door Zones)
49. – 64. New
140. – 147. 4 Button
148. – 155. New (Button Zones)
180. – 185. Temperature (Z-Wave Thermostat zones) (L5200 only)
180. – 187. Temperature (Z-Wave Thermostat zones) (L7000 only)
95. Fire
96. Medical
99. Police
3. Select a zone and then select “Edit” or “Add New” to program the next available zone. The
following options are displayed (dependant upon Zone Type):
Serial Number *
Loop Number *
*
This field does not apply to
Hardwire Zone 1 or
Temperature Zones 80-85.
Zone Description 1
Zone Description 2
Device Type
Response Type
Alarm Report
Chime
Supervision
4. Select an option to display the next programming field.
Serial Number
Serial Number
(This field does not apply to Temperature Zones 80-85)
When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed. The
transmitter serial number and loop number can be enrolled via RF transmission OR manually.
Enroll via RF Learning
To enroll the device using RF Learning mode three transmissions
(open/close) of the device will be required. The initial transmission activates the RF Learning
mode and the system will emit a single beep. A second transmission enrolls the serial number
and the system beeps two times and displays “Activate Sensor Again To Confirm”. A third
transmission will confirm the serial number. The system beeps two times and returns to the
Zone programming Screen.
Enroll Manually
Enter the 7-digit serial number printed on the transmitter using the displayed keypad and
select “Done”. The system beeps one time and returns to the Zone programming Screen.
Loop Number
1
Loop Number
(This field does not apply to Temperature Zones 80-85)
Select “Loop Number” to toggle between 1, 2, 3 and 4. Enter Save.