Zone Response Type Definitions
Type Function
Characteristics
Arm–Stay
Special-purpose zone type used with 5800 Series
wireless pushbutton units.
•
Exit delay regardless of the arming mode selected.
•
System is armed in the STAY mode when the zone is activated.
Arm–Away
Special-purpose zone type used with 5800
Series wireless pushbutton units.
•
System is armed in the AWAY mode when the zone is activated.
Disarm
Special-purpose zone type used with 5800
Series wireless pushbutton units.
•
Disarms the system when the zone is activated.
No Alarm Response Assigned when no-alarm response is required
•
No reports to the central station.
•
No keypad sounding or chime
•
System can still be armed
•
No display on the screen
Silent Burglary
Usually assigned to sensors or contacts on
exterior doors and windows where sirens are NOT
desired.
•
Instant alarm, with NO audible indication when is armed in the
AWAY, STAY, STAY NO DELAY, NIGHT STAY, or AWAY INSTANT
mode.
•
Report sent to the central station.
Monitor
Can be assigned to any wireless zone used for
asset protection. Works as a dynamic monitor of a
zone fault/trouble (not alarm).
•
Reports to the central station, if enabled.
•
Fault/restore events are logged by the system.
•
Activity Zone No. and Zone Descriptor displayed on LCD.
•
Restore will be stored in event log.
•
No keypad sounding or chime
•
System can still be armed
General Monitor
Assigned sensors or contacts on doors and
windows or asset protection within the premises.
Used to track activity of the occupant and alert
occupant of the activity of others.
•
No reports to the central station.
•
Fault/restore events are logged by the system.
•
Monitors entry into a monitored area. Activates a one-time
announcement when faulted.
•
Activity Zone No. and Zone Descriptor displayed on LCD.
General Response
Assigned sensors or contacts on doors and
windows or asset protection within the premises.
Used to track activity of the occupant and alert
occupant of the activity of others.
•
No reports to the central station.
•
Fault/restore events are logged by the system.
•
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
•
Activity Zone No. and Zone Descriptor displayed on LCD.
•
System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless key button).
Resident Monitor
Used to monitor a resident in an area deemed to
be dangerous by a caregiver.
•
No reports to the central station.
•
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
•
Activity Zone No. and Zone Descriptor displayed on LCD.
•
Fault/Restore events are not logged by the system.
Resident Response Used to monitor a resident in an area deemed to
be dangerous by a caregiver. Requires
acknowledgement by caregiver.
•
No reports to the central station.
•
Monitors entry into a monitored area. Activates a zone announcement
when faulted.
•
Activity Zone No. and Zone Descriptor displayed on LCD.
•
System re-triggers audible sounding every ten seconds until
acknowledged (Off sequence or wireless key button).
•
Fault/Restore events are not logged by the system
Trouble
Used with Other response type
•
The system will provide a trouble sounding from the keypad (and a
central station report, if desired).
Garage (Burglary)
Assigned to Automatic Garage Door applications.
Provides a status of the garage door close/open
real time state
•
Associated With Entry Delay #2 Programmed Time.
•
Exit delays when armed in AWAY, STAY or
NIGHT STAY
mode.
•
No Entry Delay when armed in Away or Stay Instant modes
•
System can be armed with zone in the faulted state. When the zone is
closed it will automatically be inclusive within protection points. If the
point is subsequently violated, it will initiate an alarm.
•
Zone type can be bypassed by any User Code except Babysitter.
Garage Monitor
Assigned to Automatic Garage Door applications.
Provides a status of the garage door close/open
real time state
•
Can be assigned to any wireless zone used for automatic “Garage
Door” Open/Close status.
•
Will not initiate an alarm condition on the control.
•
When zone is in the open state will display “FAULT.”
•
Does not report alarms to central station.
•
Zone will chime if enabled to do so
•
System can be armed if this zone type is in fault
•
Zone can be Bypassed by a valid code except babysitter