LYNX Touch Installation and Setup Guide
- 48 -
Programming the Control
Program System Settings
The following system options are programmed in this section:
Option Function
Entry Delay1/Entry Delay 2
Selects an Entry Delay time in seconds.
The system will wait the time entered before
sounding alarm upon entering if system is not disarmed.
Note:
The Default values differ for the L5200/L7000 and L5200CN/L7000CN controls.
Exit Delay
Selects an Exit Delay time in seconds for both Entry Delay 1 and 2 Zone Types.
The
system will wait the time entered before sounding an alarm if the exit door is left open after
the system has been armed.
Note:
The Default values differ for the L5200/L7000 and L5200CN/L7000CN controls.
Backlight Timeout
Enable or disable display backlight turnoff after 30 seconds.
Quick Arm
Enables or disables Quick Arm Mode.
If enabled, security code is not required to arm the
system. The user simply presses the AWAY button (ICON) and then selects the “Quick
Arm” button on the displayed keypad to arm the system.
Quick Exit
Enables or disables Quick Exit Mode. If enabled allows the user restart the exit delay to
allow entry or exit when the system is armed
Restart Exit Time
Enables or disables Restart Exit Time Mode.
This option allows the control to restart the
exit delay time after arming in STAY mode by entering the User Code and pressing the
STAY key (if quick arming is disabled) or by pressing the STAY key (if quick arming is
enabled). This option also enables automatic exit delay reset, which resets exit delay if the
entry/exit door is re-opened and closed before exit delay time expires after arming.
Force Bypass
Enables or disables Force Bypass Mode.
All zones bypassed by this function will be
displayed after the bypass is initiated. The Fire and CO Zones are not bypassed in the
L5200/L7000.
Exit Warning
Enables or disables Exit Warning sound.
Audible Exit Warning sound consists of slow
continuous beeps until last 10 seconds, when it changes to fast beeps. The warning sound
will end at the termination of exit delay.
Note:
This field is not programmable in the L5200/L7000 and is always enabled.
Auto Stay Arming
Enables or disables Auto Stay Arming Mode.
If this feature is enabled and the control panel
has been armed “Armed Away” at the LYNX Touch keypad or RF keypad, the system will
switch to the “Armed Stay” mode if the Exit Time has expired and no exit has been made.
Lack of Usage Notify
Enables or disables Lack of Usage Notification feature.
If enabled, notifies the central
station if an end user is not operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone number and only if Contact
ID® format was selected.
Power-Up in Previous
Enables or disables Power-Up in Previous Mode feature. When the system powers up
armed, an alarm will occur 1 minute after arming if a zone is faulted. For the
L5200
CN
/L7000
CN
control any bypassed zones will be unbypassed. For the L5200/L7000
any bypassed zones will remain bypassed.
Display Alarm Cancel
Enables or disables display of Cancelled Alarm.
Display Exit Time
Enables or disables display of Exit Time.
Cross Zone Delay
Sets the maximum amount of time in which two zones must be tripped in an armed system
to send an alarm message to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is sent to the Central Station.
Cross Zone 1/Cross Zone 2
Select the zones that will be used for Cross Zoning