LYNX Touch Installation and Setup Guide
- 10 -
AC Power and Backup Battery
General
The system is powered by a 9 Volt DC, 2.7 Amp Plug-in Power Supply, 300-04705/300-04705V1, or 300-
04065/300-04065V1 (300-04063/300-04063V1 or 300-04064/300-04064V1 in Canada). Refer to the wiring
table below for wire gauge and length. In the event of an AC power loss, the system is supported by a long
life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing,
or a low battery condition is detected, a “low battery” message is displayed and a report is sent to the central
station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition
(press any key to stop the beeping).
Use only the provided 300-04705/300-04705V1, or 300-04065/300-04065V1 (300-04063/300-04063V1 or 300-
04064/300-04064V1 Canada)
Power Supply. Do not plug the power supply into the AC outlet until after all
wiring connections have been made. Ensure the cover is snapped closed prior to applying AC power.
The LYNX Touch is equipped with an integral, replaceable, rechargeable battery pack
rated at 7.2Vdc.
Select the appropriate battery pack, based on the installation’s requirement, and install the battery pack.
Refer to the appropriate figure for the LYNX Touch L5200 OR L7000 control.
Installing the Rechargeable Backup Battery
1. Remove
battery retainer.
2. Insert
battery
pack into back case.
3. Install battery retainer.
4. Secure battery retainer with the provided screw.
5. Secure
battery
wiring in the wire routing clips (3).
6. Connect the battery connector to the receptacle on the PC board.
7. After the wiring connection has been made, snap the front and the back case closed.
8.
Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-up, the system will display “Checking
System Integrity” and then the “System Standby!” screen will be displayed
.
Replacing the Rechargeable Backup Battery
1.
When battery replacement is required, unplug the power supply from the wall outlet, and open the control panel cover.
2.
Disconnect the battery pack connector from the receptacle on the PC board.
3. Remove the screw that secures the battery retainer and remove the battery retainer.
4. Remove the battery pack from the back plate.
5. Install a replacement battery pack (P/N 300-0364-1/LYNXRCHKIT-SC OR P/N 300-0366/ LYNXRCHKIT-SHA) into the
back case.
6. Route the battery cable through the channel (cutout) on the left side of the compartment.
7. Install the battery retainer.
8. Secure battery retainer with the provided screw.
9. Secure battery wiring in the wire routing clips (3).
10. Connect the battery connector to the receptacle on the PC board.
11. After the wiring connection has been made, snap the front and the back case closed.
12. Plug the power supply into a 24-hour, 110VAC unswitched outlet. Upon power-up, the system will display “Checking
System Integrity” and then the “System Standby!” screen will be displayed.
Ensure the control panel assembly is snapped closed prior to applying AC power. Rechargeable batteries
may take up to 48-hours to fully charge. The “Low Battery” message should clear within four hours or by
entering Test Mode.
Battery Selection
The LYNX Touch L5200 and L7000 controls are equipped with an integral, replaceable, rechargeable battery pack
rated at 7.2Vdc. Select the appropriate battery pack, based on the installation’s requirement, and install the battery
pack.
Battery Part Number
Battery StandbyTime
Low Battery Notification
300-03864-1/LYNXRCHKIT-SC
4-hours (minimum)
Approximately 1-hour before battery depletion
300-03866/LYNXRCHKIT-SHA
24-hours (minimum)
At least 1-hour before battery depletion