LYNX Touch Installation and Setup Guide
- 81 -
SIA Quick Reference Guide
Programming Section
Feature
Range
Shipping Default
SIA Requirement
Installation and Setup Guide or Programming Guide
Reporter
/
Report Selection
Exit Error
Enabled or Disabled
Enabled
Enabled
Recent Closing
Enabled or Disabled
Enabled
Enabled
Alarm Cancel
Enabled or Disabled
Enabled
Enabled
Reporter
/Options
Call Wait Cancel
Enabled or Disabled
Field is blank (a PBX prefix
is entered to enable)
Enabled if User has call
waiting
Number of Reports
1 to 6 Reports
2 Reports
2 Reports
Alarm Report Delay
(Abort Window)
15, 30 and 45 seconds
30 Seconds
30 Seconds*
System Settings
Entry Delay # 1
None, 30, 45, 60 and 90
seconds and 2, 3 or 4
i
t
30 Seconds
30 Seconds minimum
Entry Delay # 2
None, 30, 45, 60 and 90
seconds and 2, 3 or 4
30 Seconds
30 Seconds minimum
Exit Delay
45, 60, 90 seconds and 2
minutes
60 Seconds
45 seconds minimum
Restart Exit Time
Enabled or Disabled
Yes (Enabled)
Enabled
Exit Warning
Not selectable
Always enabled
Enabled
Auto Stay Arming
Enabled or Disabled
Yes (Enabled)
Enabled
Cross Zone Delay
30 seconds and 2 minutes
(in 30 second increments),
3 minutes and 4 minutes
None (Disabled)
Enabled and two zones
programmed
Zones
Fire Alarms
Zone Type “Fire with
Verification” must be
selected for Fire Zone 95
Disabled Disabled
User Guide
User Functions/
User Access
Duress
Duress Code is
Programmed by Master
User as User 16
Disabled Disabled
System Functions/
Testing the System**
System Test
System tests provided as a
User Function
n/a n/a
Communications
While the system is in Test
mode, no alarm reports are
sent to the central station
Disabled Disabled
* Combined Entry Delay and Alarm Report Delay (Abort Window) should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.
Note:
Using the Call Waiting Cancel feature on a non-Call Waiting line will prevent successful communication to the central station.