LYNX Touch Installation and Setup Guide
- 19 -
Installing Wireless Zones
5800 Series Transmitter Loop Numbers
(Refer to this information when programming transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop
designations.
LOOP 1
5806/5806W3/5807
5808/5808LST/5808W3
ENROLL A
S
"RF"
LOOP 1
LOOP 1
5809
ENROLL A
S
"RF"
5 8 1 8 M N L
ENROLL A
S
"RF"
LOOP 1
LOOP 1
LOOP
S
1 -
3
LOOP 1
LOOP 1
5814
ENROLL A
S
"RF"
5
8
00-002-V2
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL A
S
"BR"
PROGRAM HOU
S
E ID
LOOP 4
LOOP
3
LOOP 1
LOOP 2
•
•
••
•
•
••
•
•
•
• •
• •
•
•••
5804E
ENROLL A
S
"BR"
5 8 2 2 T
ENROLL A
S
"RF"
5 8 7 7
5 8 1 6 M N
ENROLL A
S
"RF"
LOOP 1
(TERMINAL
S
)
ALTERNATE
PO
S
ITION
FOR LOOP 2
LOOP 2
(REED)
LOOP
3
(TERMINAL
S
)
5 8 2 8 / 5 8 2 8 V
P RO G R A M
HOU
S
E ID
5 8 2 1
ENROLL A
S
"RF"
5 8 2 0 L
ENROLL A
S
"RF"
5 8 1 9 S ( W H S & B R S )
ENROLL A
S
"RF"
LOOP 1
(INTERNAL
S
HOCK
S
EN
S
OR
LOOP 2
(REED)
5 8 1 9
ENROLL A
S
"RF"
LOOP 2
(REED)
LOOP
3
(TERMINAL
S
)
LOOP 1
(TERMINAL
S
)
5 8 0 0 WAV E
P RO G R A M
H O U
S
E I D
5 8 0 0 P I R - O D
E N R O L L A
S
" R F "
5 8 0 0 P I R / 5 8 0 0 P I R - C O M
E N R O L L A
S
" R F "
5 8 1 1
E N R O L L A
S
" R F "
5 8 0 0 P I R - R E S
E N R O L L A
S
" R F "
5 8 0 0 M i c r a
E N R O L L A
S
" R F "
5 8 0 0 C O
E N R O L L A
S
" R F "
5 8 0 0 S S 1
E N RO L L A
S
" R F "
5 8 0 0 R L
S
E T H O U
S
E I D
LOOP 1
LOOP 1
(LOW
S
EN
S
ITIVITY
LOOP 2
(HIGH
S
EN
S
ITIVITY)
LOOP
3
(TEMP)
LOOP 4 (TAMPER)
LOOP 1
(HIGH
S
ECURITY)
LOOP 2
(
S
TANDARD
S
ECURITY)
LOOP
3
(TILT MODE)
LOOP 4 (TAMPER)
LOOP 1
(LOW
S
EN
S
ITIVITY
LOOP 2
(HIGH
S
EN
S
ITIVITY)
LOOP
3
(TEMP)
LOOP 4 (TAMPER)
5834-2
ENROLL A
S
"BR"
5834-4
ENROLL A
S
"BR"
LOOP
1
LOOP
1
LOOP
1
LOOP
1
5 8 7 8
ENROLL A
S
"BR"
5870API
ENROLL A
S
"RF"
5869
ENROLL A
S
"RF"
5 8 5 3
ENROLL A
S
"RF"
ARMED
READY
MESSAGE
MIC
LOOP 1
(LOW
S
EN
S
ITIVITY)
LOOP 2
(HIGH
S
EN
S
ITIVITY)
5 8 9 8
ENROLL A
S
"RF"
LOOP 4
LOOP 1
LOOP 2
LOOP
3
S
ERIAL #1
LOOP
3
S
ERIAL #1
LOOP 4
S
ERIAL #2
LOOP
3
S
ERIAL #1
LOOP 2
S
ERIAL #1
LOOP 1
S
ERIAL #2
LOOP 2
3
AWA
Y
ST
AY
1
2
4
OFF
ON
S
ERIAL #1
LOOP 4
S
ERIAL #2
LOOP 1
S
ERIAL #2
LOOP 2
S
ERIAL #2
LOOP
3
S
ERIAL #1
LOOP 1
S
ERIAL #2
LOOP 4
LOOP
3
5 8 1 6
ENROLL A
S
"RF"
LOOP 1
(TERMINAL
S
)
LOOP 2
(REED)
S
ERIAL #2
LOOP 1
S
ERIAL #1
LOOP
3
S
ERIAL #1
LOOP 2
Notes:
(1)
The 5806W3 smoke detector must be used in SIA applications.
(2) Button type (BR) devices send only fault and low battery signals; no restore or check-in signals.
Supervised RF (RF) devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised RF (UR) devices send periodic check-in signals, faults, restore and low battery signals but the control does not
supervise the check-in signals.
(3)
If an external sounder is required, the 5800WAVE should be used.
(4)
The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is in Go-No-Go Test Mode. Refer
to the transmitter’s Installation Instruction for complete details. The system will confirm the enrollment of the encrypted device
by beeping two times
(5)
The 5800PIR-OD, 5800RL, 5800SS1, 5804E, 5804BD, 5804BDV, 5814, 5816TEMP, 5821, 5822T and 5828/5828V, 5877,
5878 wireless transmitters have not been evaluated by UL/ETL.