Rev. 1.00
297 of 576
January 28, 2022
32-Bit Arm
®
Cortex
®
-M0+ MCU
HT32F54231/HT32F54241/HT32F54243/HT32F54253
15 Motor Control T
imer (MCTM)
15 Motor Control T
imer (MCTM)
Capture Counter Value Transferred to CHxCCR
When the channel is used as a capture input, the counter value is captured into the Channel
Capture/Compare Register (CHxCCR) when an effective input signal transition occurs. Once the
capture event occurs, the CHxCCIF flag in the INTSR register is set accordingly. If the CHxCCIF
bit is already set, i.e., the flag has not yet been cleared by software, and another capture event on
this channel occurs, the corresponding channel Over-Capture flag, named CHxOCF, will be set.
25
26
27
28
29
30
31
32
33
34
35
0
26
32
CNTR
CHxCCR
CHxCCIF
CHxOCF
MT_CH0
(TI0)
Figure 87. Input Capture Mode