7
8
Installation Instructions
Operator’s Manual
monty 5800
i-1
i. Installation requirements.
THE INSTALLATION SHALL BE CARRIED OUT ONLY
BY QUALIFIED PERSONNEL AND WITHIN THE
SCOPE OF THE INSTRUCTIONS PROVIDED IN
THIS MANUAL.
Install the machine in a covered and dry area.
The installation of the machine requires a free space of
at least 5000x7000 mm (
Fig.i-1
).
Only for BA model
the space must be
6000x7000
(
Fig. i-1
).
Make sure that from the operating position the user
can see all of the machine and the surrounding area.
The operator shall forbid, in such an area, the presence
of non authorized persons and of objects which may
create possible hazards.
The machine shall be installed on a horizontal floor
preferably even. Do not install the machine on a sinking
or irregular floor.
If the machine is installed on a raised floor, the floor
must have a capacity of at least 15000 N/m
²
(1500kg/
m
²
or 330lbs
x
sqft). The machine must be secured to
the floor through the holes provided in the cabinet.
Expansion screws 12x120mm shall be used.
Drill 12mm holes in the floor flush with the holes provided
in the cabinet.
Place the nogs into the holes drilled in the floor and
move the machine so that the holes of the cabinet are
flush with the holes in the floor. Tighten the screws at
70 Nm
(51 ftxlbs)
.