Operation manual geodyna 2350 - 9413 126
Controls and displays
13
14
15
1
4
2
3
1
2
3
4
5
6
7
4.
Controls and displays
Fig. 13
Overview
1
START
key
Start a measuring run
2
STOP
key
- Interrupt the measuring run
- Delete an error code
- If input of a mode of operation is completed with
the STOP key, the new state is deselected
automatically and the former state is re-established.
3
Function keys (see
Fig. 14
to
16
)
4
Display (see
Fig. 17
to
20
)
Fig. 14
Function keys on the left
1
Function key for
distance rim / machine
2
Function key for
rim width
3
Function key for
rim diameter
Fig. 15
Function keys in the middle
4
PRO MATCH
- Starts an optimisation program (LED PRO MATCH
lights).
- In the Pro-Match program:
enter valve position.
5
CLEAR/RESTORE
CLEAR
(key pressed briefly): Setting the factory adjusted
modes of operation. All settings are deleted and the display
returns to standard.
RESTORE
(key pressed for 3 seconds): Restores all
modes the way they were before clear was pressed.
6
CALIBRATE/CODE
CALIBRATE
(key pressed briefly): Sets the machine in the
user calibration mode (see § 13. User calibration).
CODE
(key pressed for 3 seconds): Switches to changing
modes of operation.
7
G/OZ
Switches over the weight unit for unbalance readings
(grammes or ounces).
G
Readings in grammes
Oz
Readings in ounces
When the machine is switched on the weight unit set with
code C3 is active.