56
Operation manual geodyna 2350 - 9413 126
Pro-Match/
Weight minimisation
START
130
131
Reading Un.5 - reference mark (Fig. 130)
D
After the measuring run index the wheel following the
position reading and provide a crayon mark on the right
side of the tire at 12:00 o’clock.
D
Readjust the tire on the rim such that the tire mark co-
incides with the valve.
D
Clamp the tire/rim assembly on the balancer and read-
just such that the valve is at 12:00 o’clock.
D
Press the PRO MATCH key to enter the valve position.
Reading Un.6
(Fig. 131)
comes up.
D
Press the START key.
The second measuring run of the tire/rim assembly is started.
After the measuring run three readings are possible:
=== - Un.7
(see Fig. 132)
Proceed with the Un program. It is recommended that the tire be
turned over on the rim.
Un.7 - ===
(see Fig. 133)
Proceed with the Un program. It is recommended that the tire be
adjusted on the rim.
H 0
(see Fig. 134)
Optimum condition has been achieved and cannot be im-
proved.
Depending on the readings, there are several possibilities for
proceeding with the program. These possibilities are described
below.