30
Operation manual geodyna 2350 - 9413 126
Balancing the wheel
56
57
15.5
7.5
15.5
ALU
D
Swing the gauge arm out towards the rim and press the
weight firmly against the rim using the ejector
(Fig. 55,
item 5)
.
D
Swing the gauge arm in and return it to its home position.
D
Firmly press the adhesive weight on the rim by hand.
8.2.3 How to fit adhesive weights based on given
dimensions
If the correction positions are not accessible with the gauge arm
and the rim dimensions have been entered using the function
keys and rotating the wheel:
D
Fit adhesive weights in the given positions according to
the balancing mode. Make sure to observe the given
positioning dimensions
(Fig. 56)
8.3
Check run
D
When the balance weights are fitted, start a check run.
On completion of the check run when the wheel is perfectly bal-
anced, both digital displays show 0 and the OK indicators come
up
(Fig. 57)
.
Note
If both amount readings are 0, but there is no OK reading, dy-
namic unbalances below the tolerance limit (suppression
preset to 1/4 ounce) add to a static unbalance above the toler-
ance limit. These residual unbalances are read out upon oper-
ation of the FINE key (Fig. 16b, item 11) and should then be bal-
anced.