14
Operation manual geodyna 2350 - 9413 126
Turning on the machine
22
23
24
25
26
27
1
5.
Turning on the machine
When switched on by the mains switch
(Fig. 22, item 1)
the
electronic unit performs a number of self-tests. On successful
completion of these tests a melodious three-tone signal is
given. OK is read out on the displays, and the code number of
the program version is briefly viewed on the display; then both
displays show wheel dimensions which were entered before
and are still stored in the electronic memory.
As long as the machine is carrying out the self-tests, no inputs
and no other operations whatsoever must be made. During this
starting phase the machine must not be subjected to even the
slightest vibration.
The electronic unit is factory-adjusted to the following modes of
operation, which are available after turning on:
-
car wheel with nominal dimensions in inches, width 6.5
and diameter 15.0
-
entry of rim data in inches
-
display of amount of unbalance in 1/4 ounce increments
-
suppression of minor unbalance readings (limit set to
1/4 ounce)
-
compensation of adapter unbalance switched off
-
start of measuring run by START key
Error codes at power on
If an error code occurs it must be acknowledged by pressing the
STOP key. No audible signal is given.
The following malfunction codes may occur at power-on:
E900 - Fig. 23
Unknown machine model.
E901 - Fig. 24
The machine is not calibrated.
E89 - Fig. 25
A key is jammed at power-on.
D
Find and release the jammed key, call service if necess-
ary.
H82 - Fig. 26
The self-test was disturbed (e.g. by rotating the wheel).
The message is displayed for 3 seconds, after which the
measurement is repeated (max. 10 times), or aborted by press-
ing the STOP key.
E3 - Fig. 27
Distance gauge arm is not in home position.
D
Move gauge arm to its home position. Press the STOP
key to continue.