10
Operation manual geodyna 2350 - 9413 126
Controls and displays
11
16b
Fig. 16b
Function keys on the right
11 FINE/INT
FINE
(pressed on top):
- Show amount reading with higher resolution:
1 gramme instead of 5 grammes or 0.05 oz instead of
0.25 oz (only for as long as the key is pressed)
- Display residual wheel unbalance below the threshold
for suppression of minor unbalance readings:
As long as the key is pressed the suppression of minor
unbalance readings is switched off and the actual unbal-
ance in the wheel is read out.
- Display unbalance for standard balancing mode:
if balancing mode Alu 1 to Alu 5 is selected, press and
hold the FINE key and then press the function key for
balancing mode (ALU, ALU+). The unbalance readings
switch over to those for standard balancing mode and
the relative rim symbol appears.
- In the OP and Un programs the FINE key serves as
change-over key.
INT
(pressed on bottom):
Switches to the patch balance mode.
All wheel data must have been entered. In addition the
height-to-width ratio specified on the tire has to be en-
tered by pressing the diameter key and rotating the
wheel.
Readout display changes to single-plane. Both location
displays are active and work in parallel. Distance and di-
ameter dimensions have no effect and are preset to
nominal values. All special functions are inactive and
cannot be selected.