26
Operation manual geodyna 2350 - 9413 126
Entry of balancing mode and wheel size
48
3
2
1
5
4
Fitting of balance weights
The weight for
AP1
is a hammer-on weight and is attached at
12:00 o’clock to the main shaft after indexing the wheel, as in
the normal mode. The gauge arm stays in its home position.
The adhesive weight for
AP2
is fitted as described below:
D
Index the wheel to the correction position in the left
correction plane. On reaching the correction position
only the two arrow-heads light up (see § 8.1 Measure-
ment).
D
Press the pedal of the main shaft lock to hold the wheel in
this position.
D
Clean the position before attaching the adhesive
weights.
D
Select an adhesive weight and adjust it to the wheel
radius by bending.
D
Raise the gauge arm
(Fig. 48, item 1)
and pull the hold-
ing ring of the gauge
(Fig. 48, item 2)
inwards.
D
Insert the adhesive weight
(Fig. 48, item 3)
into the
gauge with the protective tape facing upwards to the
arrow
(Fig. 48, item 4)
.
D
Press the adhesive weight firmly into the gauge and re-
move the protective tape from the weight.
D
Pull the gauge arm towards application position
AP2
.
The display shows the dimension for the first distance, which
decreases as the gauge is approached. At 0
±
1 an audible sig-
nal is given to show that
AP2
has been reached.
D
Swing the gauge arm out towards the rim and press the
weight firmly against the rim using the ejector
(Fig. 48,
item 5)
.
D
Swing the gauge arm in and return it to its home position.
D
Firmly press the adhesive weight on the rim by hand.