60
Operation manual geodyna 2350 - 9413 126
Maintenance
·
Technical data
140
420
750
14. Maintenance
The wheel balancer requires almost no maintenance. Their
bearings are greased for life and sealed. The drive belt does not
require particular checks. If defects occur which cannot be elim-
inated by the user (error codes not mentioned under § 11. Error
codes), contact your local Hofmann distributor or Hofmann for
service at the numbers listed below.
14.1 After-sales service
Please contact your local agent (see last page).
In the USA:
Hofmann - USA
PO Box 178157
Nashville, TN 37217
Phone:
Fax:
www.hofmann-usa.com
In Canada:
Hofmann - Canada
PO Box 1270
Belleville, Ontario K8N 5E9
Phone: 613 962 9138
Fax: 613 962 8302
www.hofmann-ca.com
15. Technical data
Machine dimensions
see Fig. 140
Height of machine
40 inches
Weight of machine
150 lbs
Power required
115 - 120 V 50/60 Hz
Motor rating
0.12 kW
Balancing speed
98 rpm
Measuring time
7 s
Max. unbalance reading
14 oz
Resolution of amount reading
1/5 g or 0.05/0.25 oz
Resolution of position reading
0.7 deg.
Working temperature
0-50
°
C
Relative humidity
5-95 % at 40
°
C
Noise level
70 dB (A)
Working range
Distance rim - machine
0-250 mm
Rim width
1-20 inches
Rim diameter
8-24 inches
Max. wheel diameter
44
inches
Max. wheel diameter with optional
wheel guard
37
inches
Max. wheel width
20
inches
Max. wheel weight
150 lbs
Fig. 140
Dimensions of wheel balancer
615-331-7851
615-331-8176