H5RS485 Card & RS485Communication Protocol
100C
AI3 voltage
100D
Counting value input
100E
Length value input
100F
Load speed
1010
PID setup
1011
PID feedback
1012
PLC process
1013
PULSE input pulse frequency, unit 0.01kHz
1014
Feedback speed, unit 0.1Hz
1015
Rest running time
1016
AI1 voltage before correction
1017
AI2 voltage before correction
1018
AI3 voltage before correction
1019
Line speed
101A
Current power on time
101B
Current running time
101C
PULSE input pulse frequency, unit 1Hz
101D
Communication setup value
101E
Actual feedback speed
101F
Main frequency X display
1020
Auxiliary frequency Y display
Caution
:
The communication setup value is percentage of the relative value, 10000 corresponds
to 100.00%
,
-10000 correspondsto -100.00%.For data of dimensional frequency,the
percentage value is the percentage of the maximum frequency.For data of dimensional
torque, the percentage is P2.10, A2.48, A3.48, A4.48 (Torque upper digital setup,
corresponding to the first, second, third, fourth motor).
Control command input to the inverter (write-only)
Command word address
Command function
2000
0001
:
Forward operation
0002
:
Reverse operation
0003
:
Forward jog
0004
:
Reverse jog
0005
:
Free stop
0006
:
Speed-Down stop
0007
:
Fault reset