110
Section V.
Parameter Function Table
UP/DOWN can be modified
It is used to select the reference channel of MS speed 0.
Besides choosing PC.00, MS command 0 has many other options, which is convenient for switching
between MS command and other set modes.
Both MS command and simple PLC used as frequency source can easily realize switching between
the two frequency sources.
5.15
Communication function group
:
Pd.00-Pd.06
Please refer to
《
HV590communication protocol
》
Code
Description/
Keyboard Display
Setting Range
Factory
Setting
Change
Limit
Pd.00
Baud rate
1bit
MODBUS
6005
☆
300BPS
0
600BPS
1
1200BPS
2
2400BPS
3
4800BPS
4
9600BPS
5
19200BPS
6
38400BPS
7
57600BPS
8
115200BPS
9
10bit
Profibus-DP
115200BPS
0
208300BPS
1
256000BPS
2
512000BPS
3
100
bit
Reserved
1000
bit
Reserved
Pd.01
Data format
Without calibration (8-N-2)
0
0
☆
Even parity calibration(8-E-1)
1
Uneven parity calibration(8-O-1)
2
8-N-1
3
Pd.02
Local address
1-247, 0 is broadcast address
1
☆