4-20
Chapter 4
For parameter configuration
[AF120]
~
[AF144]
Brake control function
Code/Name
Range (unit)
Initial
value
AF120
Contactor control
enable, 1st-motor
00(Disable)
01(Enable: primary side)
02(Enable: secondary side)
00
AF121
Run delay time,
1st-motor
0.00
~
2.00(s)
0.20
AF122
Contactor off
delay time, 1st-motor
0.00
~
2.00(s)
0.10
AF123
Contactor answer
back check time, 1st-motor
0.00
~
5.00(s)
0.10
AF130
Brake control enable,
1st-motor
00(Disable)/
01(Brake control 1:
Common)/
02(Brake control 1:
Separate)/
03(Brake control 2)
00
AF131
Brake wait time for
release, 1st-motor (Forward)
0.00
~
5.00(s)
0.00
AF132
Brake wait time for
Acc., 1st-motor (Forward)
0.00
~
5.00(s)
0.00
AF133
Brake wait time for
Stop, 1st-motor (Forward)
0.00
~
5.00(s)
0.00
AF134
Brake wait time for
confirmation, 1st-motor
(Forward)
0.00
~
5.00(s)
0.00
AF135
Brake release frequency,
1st-motor (Forward)
0.00
~
590.00(Hz)
0.00
AF136
Brake release
current, 1st-motor (Forward)
Inverter rated current
×(0.20
~
2.00)
*1)
AF137
Brake frequency,
1st-motor (Forward)
0.00
~
590.00(Hz)
0.00
AF138
Brake wait time for
release, 1st-motor (Reverse)
0.00
~
5.00(s)
0.00
AF139
Brake wait time for Acc. ,
1st-motor (Reverse)
0.00
~
5.00(s)
0.00
AF140
Brake wait time for
Stop, 1st-motor (Reverse)
0.00
~
5.00(s)
0.00
AF141
Brake wait time for
confirmation, 1st-motor
(Reverse)
0.00
~
5.00(s)
0.00
AF142
Brake release frequency,
1st-motor (Reverse)
0.00
~
590.00(Hz)
0.00
AF143
Brake release
current, 1st-motor (Reverse)
Inverter rated current
×(0.20
~
2.00)
*1)
AF144
Brake frequency,
1st-motor (Reverse)
0.00
~
590.00(Hz)
0.00
*1) Inverter rated current × 1.00.
[AF150]
~
[AF254]
Code/Name
Range (unit)
Initial
value
AF150
Brake open delay time,
1st-motor
0.00
~
2.00(s)
0.20
AF151
Brake close delay time,
1st-motor
0.00
~
2.00(s)
0.20
AF152
Brake check time, 1st-motor
0.00
~
5.00(s)
0.10
AF153
Servo lock/ DC injection time
at start, 1st-motor
0.00
~
10.00(s)
0.60
AF154
Servo lock/ DC injection time
at stop, 1st-motor
0.00
~
10.00(s)
0.60
・
Operations settings of brake control.
For more information, refer to the User’s guide.
2nd motor
When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Range
(unit)
Initial
value
AF201
DC braking enable, 2nd-motor
Same as AF101
AF202
Braking type selection, 2nd-motor
Same as AF102
AF203
DC braking frequency, 1st-motor
Same as AF103
AF204
DC braking delay time, 2nd-motor
Same as AF104
AF205
DC braking force while stopping, 2nd-motor
Same as AF105
AF206
DC braking active time at stop, 2nd-motor
Same as AF106
AF207
DC braking trigger selection, 2nd-motor
Same as AF107
AF208
DC braking force while starting, 2nd-motor
Same as AF108
AF209
DC braking active time at start, 2nd-motor
Same as AF109
AF220
Contactor control enable, 2nd-motor
Same as AF120
AF221
Activation delay time, 2nd-motor
Same as AF121
AF222
Deactivation delay time, 2nd-motor
Same as AF122
AF223
Contactor check time, 2nd-motor
Same as AF123
AF230
Brake control enable, 2nd-motor
Same as AF130
AF231
Brake wait time for release, 2nd-motor
(Forward)
Same as AF131
AF232
Brake wait time for Acc., 2nd-motor
(Forward)
Same as AF132
AF233
Brake wait time for Stop, 2nd-motor
(Forward)
Same as AF133
AF234
Brake wait time for confirmation, 2nd-motor
(Forward)
Same as AF134
AF235
Brake release frequency, 2nd-motor
(Forward)
Same as AF135
AF236
Brake release current, 2nd-motor (Forward)
Same as AF136
AF237
Brake frequency, 2nd-motor (Forward)
Same as AF137
AF238
Brake wait time for release, 2nd-motor
(Reverse)
Same as AF138
AF239
Brake wait time for Acc., 2nd-motor (Reverse) Same as AF139
AF240
Brake wait time for Stop, 2nd-motor
(Reverse)
Same as AF140
AF241
Brake wait time for confirmation, 2nd-motor
(Reverse)
Same as AF141
AF242
Brake release frequency, 2nd-motor (Reverse) Same as AF142
AF243
Brake release current, 2nd-motor (Reverse)
Same as AF143
AF244
Braking frequency, 2nd-motor (Reverse side) Same as AF144
AF250
Brake open delay time, 2nd-motor
Same as AF150
AF251
Brake close delay time, 2nd-motor
Same as AF151
AF252
Brake check time, 2nd-motor
Same as AF152
AF253
Servo lock/DC injection time at start,
2nd-motor
Same as AF153
AF254
Servo lock/DC injection time at stop,
2nd-motor
Same as AF154