2-12
Chapter 2
Installation and Wiring
2.8 Chopper Braking Resistor
•
SJ Series P1 has a built-in chopper braking circuit in model below.
P1-00044-L (004L) to P1-01240-L (022L)
P1-00041-H (007H) to P1-00930-H (370H)
•
By using an optional braking resistor, permit to use for high
regeneration load application such as lift or high speed load.
200V class
Model
P1-******
(P1-****)
Appli
cable
motor
(kW)
Min.
Resis
tor
(Ω)
Resistor
selection
Ex. (Ω)
Braking Resistor
Model
Usage
ratio
(%)
Short
period
capacity
(kW)
Rated
capacity
(kW)
00044-L
(004L)
0.4
50
180
SRB200-1
10
0.7
0.2
00080-L
(007L)
0.75
50
100
SRB200-1
10
0.7
0.2
00104-L
(015L)
1.5
35
100
SRB200-2
7.5
1.25
0.2
00156-L
(022L)
2.2
35
50
SRB300-1
7.5
2.5
0.3
00228-L
(037L)
3.7
35
35
SRB400-1
7.5
3.6
0.4
00330-L
(055L)
5.5
16
17
RB3
10
7.7
1.2
00460-L
(075L)
7.5
10
17
RB3
10
7.7
1.2
00600-L
(110L)
11
10
11.7
RB2 ×3
parallel
10
11.4
1.8
00800-L
(150L)
15
7.5
8.5
RB3 ×2
parallel
10
15.4
2.4
00930-L
(185L)
18.5
7.5
8.5
RB3 ×2
parallel
10
15.4
2.4
01240-L
(220L)
22
5
5.7
RB3 ×3
parallel
10
23.1
3.6
When using RB2×2series×2parallel, will require in total 4 RB2 units.
•
SJ Series P1 can offer when desired a built-in chopper braking circuit
in models below.
P1-01160-H (450H) to P1-01470-H (550H)
•
Using optional braking unit or regenerative unit, permit to use on
high regenerative load application even for models without built-in
chopp
er braking circuit.
•
The table below shows an example selection of braking resistor to
output 100% of braking torque for each motor rating on list.
■
400V
Model
P1-******
(P1-****)
Appli
cable
motor
(kW)
Min.
Resis
tor
(Ω)
Resistor
selection
Ex. (Ω)
Braking Resistor
Model
Usage
ratio
(%)
Short
period
capacity
(kW)
Rated
capacity
(kW)
00041-H
(007H)
0.75
100
360
SRB200-1
×2series
10
1.4
0.4
00054-H
(015H)
1.5
100
100
SRB200-1
×2series
10
1.4
0.4
00083-H
(022H)
2.2
100
100
SRB200-2
×2series
7.5
2.5
0.4
00126-H
(037H)
3.7
70
100
SRB300-1
×2 series
7.5
5
0.6
00175-H
(055H)
5.5
70
100
SRB300-1
×2 series
7.5
5
0.6
00250-H
(075H)
7.5
35
70
SRB400-1
×2 series
7.5
7.2
0.8
00310-H
(110H)
11
35
50
RB1
×2 series
×2 parallel
10
10.4
1.6
00400-H
(150H)
15
24
35
RB2
×2 series
×2parallel
10
15.2
2.4
00470-H
(185H)
18.5
24
35
RB2
×2 series
×2parallel
10
15.2
2.4
00620-H
(220H)
22
20
25
RB1
×2 series
×4parallel
10
20.8
3.2
00770-H
(300H)
30
15
17
RB3
×2 series
×2parallel
10
30.8
4.8
00930-H
(370H)
37
15
17
RB3
×2 series
×2parallel
10
30.8
4.8
01160-H
(450H)
45
10
10
CA-KB
(10Ω5unit)
20
45
17
01800-H
(550H)
55
10
10
CA-KB
(10Ω5unit)
20
45
17
Summary of Contents for P1-00041-H
Page 6: ...0 5 Contents Contents Memo ...
Page 42: ...2 26 Chapter 2 Installation and Wiring Memo ...
Page 129: ...Index Index 3 memo ...