4-52
Chapter 4
For parameter configuration
[Hd202]
~
[Hd241]
2nd motor
When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Range
(unit)
Initial
value
Pe
rm
. M
ag
ne
t S
yn
c.
M
ot
or
(S
M
/P
M
M
)
Hd202
Sync. Motor capacity setting, 2nd-motor
Same as Hd102
Hd203
Sync. Motor poles setting, 2nd-motor
Same as Hd103
Hd204
Sync. Base frequency setting,
2nd-motor
Same as Hd104
Hd205
Sync. Maximum frequency setting,
2nd-motor
Same as Hd105
Hd206
Sync. Motor rated voltage,
2nd-motor
Same as Hd106
Hd208
Sync.Motor rated current,
2nd-motor
Same as Hd108
Hd210
Sync.Motor constant R, 2nd-motor Same as Hd110
Hd212
Sync.Motor constant Ld,
2nd-motor
Same as Hd112
Hd214
Sync.Motor constant Lq,
2nd-motor
Same as Hd114
Hd216
Sync.Motor constant Ke,
2nd-motor
Same as Hd116
Hd218
Sync.Motor constant J, 2nd-motor Same as Hd118
2nd motor
When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Range (unit)
Initial
value
Hd230
Minimum Frequency for Sync.M,
2nd-motor
Same as Hd130
Hd231
No-Load current for Sync.M,
2nd-motor
Same as Hd131
Hd232
Starting Method for Sync.M,
2nd-motor
Same as Hd132
Hd233
IMPE 0V wait number for
Sync.M, 2nd-motor
Same as Hd133
Hd234
IMPE detect wait number for
Sync.M, 2nd-motor
Same as Hd134
Hd235
IMPE detect number for Sync.M,
2nd-motor
Same as Hd135
Hd236
IMPE voltage gain for Sync.M,
2nd-motor
Same as Hd136
Hd237
IMPE Mg-pole position offset,
2nd-motor
Same as Hd137
[oA-10]
~
[oA-32][ob-01]
~
[ob-04]
■
Parameter mode (o code)
・
o parameters are displayed by the [UA-11] = 01. This
configuration is not necessary except when option is
used.
・
For more information, refer to the User’s guide of the
corresponding option.
Optional board error operation
Code/Name
Range (unit)
Initial
value
Sl
ot
1
oA-10
Operation
selection on option card
error (SLOT-1)
00(Error)/
01(Continue operation)
00
oA-11
Communication
Watch Dog Timer (SLOT-1)
0.00
~
100.00(s)
0.00
oA-12
Action selection
at communication error
(SLOT-1)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00
oA-13
RUN command
selection at start up
(SLOT-1)
00(Disable)/
01(Enable)
0.00
Sl
ot
2
oA-20
Operation
selection on option card
error (SLOT-2)
00(Error)/
01(Continue operation)
00
oA-21
Communication
Watch Dog Timer (SLOT-2)
0.00
~
100.00(s)
0.00
oA-22
Action selection
at communication error
(SLOT-2)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00
oA-23
RUN command
selection at start up
(SLOT-2)
00(Disable)/
01(Enable)
0.00
Sl
ot
3
oA-30
Operation
selection on option card
error (SLOT-3)
00(Error)/
01(Continue operation)
00
oA-31
Communication
Watch Dog Timer (SLOT-3)
0.00
~
100.00(s)
0.00
oA-32
Action selection
at communication error
(SLOT-3)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00
oA-33
RUN command
selection at start up
(SLOT-3)
00(Disable)/
01(Enable)
0.00
・
For more information, refer to the User’s guide.
P1-FB Optional board encoder input setting
Code/Name
Range (unit)
Initial
value
ob-01
Encoder constant setting
0
~
65535(Pulse)
1024
ob-02
Encoder position selection
00(A Phase, Cos lead)/
01(B Phase, Sin lead)
0
ob-03
Motor gear ratio
Numerator
1
~
10000
1
ob-04
Motor gear ratio
Denominator
1
~
10000
1