4-35
Chapter 4
For parameter configuration
[CA-01]
~
[CA-31]
■
Parameter mode (C code)
Input terminal settings
Code/Name
Range (unit)
Initial
value
CA-01
Input terminal [1] function
Reference
<Input
terminal
function list>
103 [PLA] Pulse
train input A is
restricted
to
[CA-10],
104 [PLB] Pulse
train input B is
restricted
to
[CA-11],
028
CA-02
Input terminal [2] function
015
CA-03
Input terminal [3] function
029
CA-04
Input terminal [4] function
032
CA-05
Input terminal [5] function
031
CA-06
Input terminal [6] function
003
CA-07
Input terminal [7] function
004
CA-08
Input terminal [8] function
002
CA-09
Input terminal [9] function
001
CA-10
Input terminal [A] function
033
CA-11
Input terminal [B] function
034
・
The functions for the input terminals 1
~
9,A,B are
assigned in [CA-01]
~
[CA-09],[CA-10],[CA-11].
Input terminal NO/NC settings
Code/Name
Range (unit)
Initial
value
CA-21
Input terminal [1] active state
00(Normally
Open: NO)/
01(Normally
Closed: NC)
00
CA-22
Input terminal [2] active state
00
CA-23
Input terminal [3] active state
00
CA-24
Input terminal [4] active state
00
CA-25
Input terminal [5] active state
00
CA-26
Input terminal [6] active state
00
CA-27
Input terminal [7] active state
00
CA-28
Input terminal [8] active state
00
CA-29
Input terminal [9] active state
00
CA-30
Input terminal [A] active state
00
CA-31
Input terminal [B] active state
00
・
The functions for the Intelligent input terminals 1
~
9,A,B are assigned in [CA-21]
~
[CA-29],[CA-30],[CA-31].
・
However, in the case of [RS] assignment the NO/NC will
not apply, only NO will apply.
[CA-41]
~
[CA-55]
Output terminal chatter prevention
Code/Name
Range
(unit)
Initial
value
CA-41
Input terminal [1] response time
0
~
400(ms)
2
CA-42
Input terminal [2] response time
2
CA-43
Input terminal [3] response time
2
CA-44
Input terminal [4] response time
2
CA-45
Input terminal [5] response time
2
CA-46
Input terminal [6] response time
2
CA-47
Input terminal [7] response time
2
CA-48
Input terminal [8] response time
2
CA-49
Input terminal [9] response time
2
CA-50
Input terminal [A] response time
2
CA-51
Input terminal [B] response time
2
・
Sets the time to wait after the input change has ended,
and for the input to become stable and responsive.
Time allowed in simultaneous terminal change
Code/Name
Range (unit)
Initial
value
CA-55
Multistage input
determination time
0
~
2000(ms)
0
・
Sets the dead time for multistage speed and position
terminals change.