4-48
Chapter 4
For parameter configuration
[Hb110]
~
[Hb131]
Induction motor constants
Code/Name
Range (unit)
Initial
value
In
du
ct
io
n
M
ot
or
(I
M
)
Hb110
Async.
Motor constant R1,
1st-motor
0.000001
~
1000.000000 (Ω)
Motor
capacity
setting
Hb112
Async.
Motor constant R2,
1st-motor
0.000001
~
1000.000000 (Ω)
Motor
capacity
setting
Hb11
Async.
Motor constant L,
1st-motor
0.000001
~
1000.000000 (mH)
Motor
capacity
setting
Hb116
Async.
Motor constant Io,
1st-motor
0.01
~
1000.00 (A)
Motor
capacity
setting
Hb118
Async.
Motor constant J,
1st-motor
0.00001
~
10000.00000 (kgm2)
Motor
capacity
setting
・
If the motor capacity[Hb102] and number of poles
[Hb103] are changed, the motor characteristics are set
according to the internal Hitachi table values.
・
For no-rotation auto-tuning, the following variables
are acquired:[Hb110]
~
[Hb114].
・
For rotation auto-tuning, the following variables are
acquired:[Hb110]
~
[Hb118]
・
It is possible to input the data obtained from the motor
manufacturer. However, it must also include the data of
the wiring and the like.
Minimum frequency setting
Code/Name
Range (unit)
Initial
value
Hb130
Minimum frequency,
1st-motor
0.00
~
10.00(Hz)
0.50
Hb131
Reduced voltage start
time, 1st-motor
0
~
2000(ms)
36
・
If the torque at the time of start-up is not enough, you
can change the settings to raise the lowest frequency.
・
Raise the minimum frequency, if the trip occurs, set a
longer time of reduced voltage start selection.
[Hb140]
~
[Hb146]
Manual torque boost adjustment
Code/Name
Range (unit)
Initial
value
Hb140
Manual torque
boost operational mode
selection, 1st-motor
00(Disabled)/
01(Enabled)/
02(Only forward)/
03(Only reverse)
01
Hb141
Manual torque
boost value, 1st-motor
0.0
~
20.0(%)
1.0
Hb142
Manual torque
boost Peak speed, 1st-motor
0.0
~
50.0(%)
5.0
・
In the manual boost operation mode only forward or
reverse boost can be selected.
・
Example [Hb140]=02
Eco Drive function
Code/Name
Range (unit)
Initial
value
Hb145
Eco drive enable,
1st-motor
00(Disable)/
01(Enable)
00
Hb146
Eco drive response
adjustment, 1st-motor
0
~
100(%)
50
・
In V/f control, if the energy saving operations is enabled,
enters an energy saving control.
FW
Output
frequency
Output
voltage
Minimum frequency
[Hb130]
00
10ms
60ms
・・・
Reduced voltage
start [Hb131]
Output
frequency
Base frequency (100%)
[Hb141]
[Hb142]
100
Output voltage (%)
Forward
Reverse
Base frequency (100%)